Small Screen pH/ORP Monitor/Meter Hot sales High Accuracy

Suitable for online monitoring of pH or ORP in purified water treatment, environmental protection water treatment, electroplating solution monitoring, chemical process, circulating cooling water, aquaculture and other industries

    Description

    Application

    Suitable for online monitoring of pH or ORP in purified water treatment, environmental protection water treatment, electroplating solution monitoring, chemical process, circulating cooling water, aquaculture and other industries

    Feature

    pH monitor/Controller

    Model FunctionPH-1100PH-1200
    Range0.00~14.00pH
    Accuracy±0.1pH
    Temp.Comp.Reference to 25 ℃, manual temperature compensation
    Oper. Temp.0~100℃
    SensorDual composite electrode
    Calibration mode4.00; 6.86; 9.18 Three-point calibration
    Display3½ Bit LCD
    Current output— — —isolation 4~20mA
    Control output— — —High/low limit relay
    PowerAC 110V±10% 50/60HzAC 220V±10% 50/60Hz
    Working environmentAmbient temperature: 0~50℃Relative humidity: ≤85%
    Dimensions48×96×100mm(H×W×D)
    Hole size45×92mm(H×W)
    Installation modeEmbedded

     

    ORP Monitor/Controller

    ModelORP-1100ORP-1200
    Range-1999~+1999mV
    Accuracy±2mV
    Oper. Temp.0~100℃
    SensorORP Electrode
    Display3½ Bit LCD
    Current output— — —Isolation 4~20mA
    Control output— — —High/Low limit relay
    PowerAC 110V±10% 50/60HzAC 220V±10% 50/60Hz
    Working environmentAmbient temperature: 0~50℃Relative humidity: ≤85%
    Dimensions48×96×100mm (H×W×D)
    Hole size45×92mm (H×W)
    Installation modeEmbedded

     

    Precautions for Sensor

    ● pH/ORP sensors are consumables. Long time storage is not suggested

    ● Sensitive glass film (glass bubble) is forbidden to use when the medium with hydrofluoric acid, fluorion and high-concentration sulfion

    ● pH/ORP sensors are not allowed to measure any organic solution which will damage or dissolve PC or ABS(such as carbon tetrachloride, trichloro ethylene or tetrahydrofuran etc.)

    ● The chemical part of the sensor is glass, please protect carefully during transportation and storage

    ● Please clean the sensor at a regular time by using swab and neutral cleanser; do not use the acid and corrosive solution to clean the sensor。

    ● High-temp. pH glass sensor is recommended for biopharmacy and high-pressure autoclaved sterilization. The protection part is optional;

    ● pH signal is weak signal, the collecting cable should run separately. Do not mix the cable together.

    ●  Measurement cable is for special use, it’s not allowed to cut or lengthened privately or replaced by other cables