Reverse Osmosis Controller for Water Purification System High Quality Single Pass Single channel

Single Pass Single channel Reverse Osmosis Controller comes with the high/low pressure flushing options for controlling the running process. 0.1/1.0/10.0 (cm-1 )three conductance cells are added for conductivity measurements to make the measurement range (low conductance (0.1~200)μS/cm and high conductance (5~9999)μS/cm) to be greatly extended.

    Description

    Single Pass Single channel Reverse Osmosis Controller comes with the high/low pressure flushing options for controlling the running process. 0.1/1.0/10.0 (cm-1 )three conductance cells are added for conductivity measurements to make the measurement range (low conductance (0.1~200)μS/cm and high conductance (5~9999)μS/cm) to be greatly extended. It is especially suitable for raw water with better water or bitter and brackish water in high conductivity area, and all this does not require complex interface menu settings, only can be obtained by hand in the rear terminal wiring..

    Feature

    * Integrated reverse osmosis control and conductivity measurement;

    * Flow chart control panel, clearly display the system process flow running status;

    * Measurement parameters and process parameters can be set, customers can flexibly

    Technical Parameter

    ROC-2100 Single Pass RO Control Systems
    Measurement Range: Conductivity: 0-20/200/2000 µs; Support with 1.0cm·1 Constant Cell Sensor
    Acquire the Signal:
    I.Raw Water Low Pressure;
    2.Pramary boosterpump inlet Low-pressure;
    3.Pramary booster pump outlet High-pressure;
    4.Pramary produce tank high level;
    5.Preprocessing Signal.
    Control Output:
    I.Inlet Valve;
    2. Flush Valve;
    3.Drain Valve;
    4.Raw Water Pump;
    5.Booster Pump
    Display method: Digital display: conductivity value/ temperature value; display RO process flow chart
    Control Power: AC220V士10% 50/60Hz AC110V土10% 50/60Hz
    Dimension:: (96*96*130) mm
    Installation Size: (92*92) mm