Conductivity / Resistivity Monitor / Controller Small Screen Hot Sales High Accuracy
High pure/ultrapure water measurement control, widely used for electronic, electric, pharmacy, fine chemistry, clinical medicine, life science.
Description
Application
● Widely used for monitoring of all water treatment process, which have high performances in high salt water treatment, concentrated solution, recirculating cooling water, reclaimed water and ect.
● High pure/ultrapure water measurement control, widely used for electronic, electric, pharmacy, fine chemistry, clinical medicine, life science.
Feature
Conductivity Monitor/Controller
Model Function | CCT-0100 | CCT-1100 | CCT-2000 |
Range | 0~20/200/2000 μS/cm; (C=1.0cm⁻¹) 0~20/200/2000 ppm; (C=1.0cm⁻¹) 0~20 mS/cm; (C=1.0cm⁻¹) 0~200 mS/cm; (C=10.0cm⁻¹) 0~20 μS/cm (C=0.1cm⁻¹) |
||
Accuracy | 1.5%(F.S.) | ||
Temp.Comp. | The 25 ℃ basis, automatic temperature compensation |
||
Oper.Temp. | 0~100℃ | ||
Sensor | S-1.0-NTC10K-MINI; JL-0.1-NTC10K; JL-10.0-NTC10K J-1.0-NTC10K-MINI; JF-0.1-NTC10K; SL-1.0-NTC10K; JL-1.0-NTC10K; JF-1.0-NTC10K; |
||
Display | 3½ Bit LCD | ||
Current output | — — — | Isolation 4~20mA | |
Control output | — — — | High limit relay | |
Power | AC 110V±10% 50/60Hz AC 220V±10% 50/60Hz |
||
Working environment | Ambient temperature:0~50℃ Relative humidity: ≤85% |
||
Dimensions | 48×96×100mm(H×W×D) | ||
Hole size | 45×92mm(H×W) | ||
Installation mode | Embedded |
Resistivity Monitor/Controll
Model Function | CCT-0100 | CCT-1100 | CCT-2100 |
Range | 0~18.25MΩ·cm | ||
Accuracy | 2.0%(F.S.) | ||
Temp.Comp. | The 25 ℃ basis, automatic temperature compensation |
||
Oper. Temp. | 0~50℃ | ||
Sensor | J-0.05-NTC-MINI; JL-0.05-NTC; JF-0.05-NTC; |
||
Display | 3½ Bit LCD | ||
Current output | — — — | Isolation 4~20mA | |
Control output | — — — | Low limit relay | |
Power | AC 110V±10% 50/60Hz AC 220V±10% 50/60Hz |
||
Working environment | Ambient temperature:0~50℃ Relative humidity: ≤85% |
||
Dimensions | 48×96×100mm(H×W×D) | ||
Hole size | 45×92mm(H×W) | ||
Installation mode | Embedded |
NOTE:
1. High pure water and ultrapure water could not select open sampling measurement method. If the high pure water is exposed to the air, a lot of carbon dioxide would dissolve into the water immediately and the impurity inside the container and dusts in the air would also dissolve into the water which could cause serious errors. So high pure water could only adopt inclosed, running and side flow circulation method. With open measurement method to test high pure water by using laboratory appliance is inadvisable.
2. Resin regeneration dirts would pollute the cell, please clean by alcohol cotton ball.