Big Screen pH/ORP Meter Hot Sales High Accuracy

Suitable for online monitoring of pH or ORP in purified water treatment, environmental protection water treatment, electroplating solution monitoring, chemical process, circulating cooling water, aquaculture and other industries

    Description

    Application

    Suitable for online monitoring of pH or ORP in purified water treatment, environmental protection water treatment, electroplating solution monitoring, chemical process, circulating cooling water, aquaculture and other industries

    Feature

    pH/ORP Controller

    Model FunctionPH/ORP-2100
    RangepH: 0.00~14.00
    ORP:-19990~+1999mV
    AccuracypH : ±0.1 pH
    ORP: ±2mV
    Temp.Comp.pH: Reference to 25 ℃,
    manual temperature compensation
    Oper. Temp.0~100℃
    SensorpH: Dual composite pH electrode
    ORP: ORP Electrode
    Calibration modepH: 4.00; 6.86; 9.18 Three-point calibration
    Display3½ Bit LCD
    Current outputIsolation 4~20mA
    Control outputHigh/low limit relay
    PowerDC24V
    AC 110/220V±10% 50/60Hz
    Working environmentAmbient temperature:0~50℃
    Relative humidity: ≤85%
    Dimensions96×96×130mm(H×W×D)
    Hole size92×92mm(H×W)
    Installation modeEmbedded

    Trouble Removal of sensor and instrument

    ProblemPossible causesTrouble shooting
    No display when powered onA.Bad connection of power supply
    B.Instrument fault
    A.check to see if there is 24Vvoltage
    between power terminals 24VA and 24VB.
    B.Check by professional technicians.
    Unstable displayA.Improper wire connection of sensor
    B.Air bubbles in the pipeline
    C.Unstable water quality
    D.Badness connection port
    A.Refer to the instruction manuals
    B.Select the proper measurement point or change the pipeline
    C.Stabilizing the water quality
    D.Check the connector to be connected
    Big deviationA.Sensor fault
    B.The cable is damaged
    C.Lncorrect installation
    D.Setting problem
    A.Take out the sensor from the pipeline and calibrate
    B.Replace the sensor which can not be calibrated
    C.Find the correct measurement point and use the flow device
    D. Reset the parameter of the instrument
    The transformer is inconsistent with the displayA.Loop resistance is too large
    B.Incorrect connection mode
    C.Unusual power supply
    D.Wrong transfervolume
    A.Replace the cable to reduce the loop resistance
    B.Check the connection right or notpowered by the standard
    C.Reset the transferred volume